siemens/mc_apl5: Disable PCI clock outputs on XIO bridges
On this mainboard there are legacy PCI device, which are connected to different PCIe root ports via PCIe-2-PCI bridges. This patch disables the unused PCI clock outputs on the XIO2001 PCI Express to PCI Bridges. Change-Id: Id36e39c4568f5dd241cd864d2e75365abd0f2a91 Signed-off-by: Mario Scheithauer <mario.scheithauer@siemens.com> Reviewed-on: https://review.coreboot.org/c/29882 Reviewed-by: Werner Zeh <werner.zeh@siemens.com> Tested-by: build bot (Jenkins) <no-reply@coreboot.org>
This commit is contained in:
parent
a94a153477
commit
1a5ce95815
|
@ -52,11 +52,6 @@ void variant_mainboard_final(void)
|
|||
*/
|
||||
pcr_write16(PID_ITSS, 0x314c, 0x0321);
|
||||
|
||||
/* Disable clock outputs 1-5 (CLKOUT) for XIO2001 PCIe to PCI Bridge. */
|
||||
dev = dev_find_device(PCI_VENDOR_ID_TI, PCI_DEVICE_ID_TI_XIO2001, 0);
|
||||
if (dev)
|
||||
pci_write_config8(dev, 0xd8, 0x3e);
|
||||
|
||||
/* Enable CLKRUN_EN for power gating LPC */
|
||||
lpc_enable_pci_clk_cntl();
|
||||
|
||||
|
@ -82,6 +77,22 @@ void variant_mainboard_final(void)
|
|||
cmd = pci_read_config16(dev, PCI_COMMAND);
|
||||
cmd |= PCI_COMMAND_MASTER;
|
||||
pci_write_config16(dev, PCI_COMMAND, cmd);
|
||||
|
||||
/* Disable clock outputs 0-3 (CLKOUT) for upstream XIO2001 PCIe
|
||||
* to PCI Bridge. */
|
||||
struct device *parent = dev->bus->dev;
|
||||
if (parent && parent->device == PCI_DEVICE_ID_TI_XIO2001)
|
||||
pci_write_config8(parent, 0xd8, 0x0f);
|
||||
}
|
||||
|
||||
/* Disable clock outputs 1-5 (CLKOUT) for another XIO2001 PCIe to PCI
|
||||
* Bridge on this mainboard.
|
||||
*/
|
||||
dev = dev_find_device(PCI_VENDOR_ID_SIEMENS, 0x403f, 0);
|
||||
if (dev) {
|
||||
struct device *parent = dev->bus->dev;
|
||||
if (parent && parent->device == PCI_DEVICE_ID_TI_XIO2001)
|
||||
pci_write_config8(parent, 0xd8, 0x3e);
|
||||
}
|
||||
}
|
||||
|
||||
|
|