haswell boards: Use PECI temp sensor id 0

The EC temperature sensors were renumbered and now PECI
is at index 0.

1) boot on falco
2) check /sys/class/thermal/thermal_zone0/temp
3) check 'temps' on ec console

Change-Id: Idde1457c42c80850b5b8ac22781060ed9b224d13
Signed-off-by: Duncan Laurie <dlaurie@chromium.org>
Reviewed-on: https://gerrit.chromium.org/gerrit/61896
Reviewed-on: http://review.coreboot.org/4367
Reviewed-by: Patrick Georgi <patrick@georgi-clan.de>
Tested-by: build bot (Jenkins)
This commit is contained in:
Duncan Laurie 2013-07-15 09:17:09 -07:00 committed by Patrick Georgi
parent a9dc05130e
commit 29f7688409
5 changed files with 6 additions and 3 deletions

View File

@ -21,7 +21,7 @@
#define THERMAL_H
/* Config TDP Sensor ID */
#define CTDP_SENSOR_ID 1 /* PECI */
#define CTDP_SENSOR_ID 0 /* PECI */
/* Config TDP Nominal */
#define CTDP_NOMINAL_THRESHOLD_OFF 0

View File

@ -44,6 +44,7 @@ unsigned long acpi_create_slic(unsigned long current);
static void acpi_update_thermal_table(global_nvs_t *gnvs)
{
gnvs->tmps = TEMPERATURE_SENSOR_ID;
gnvs->tcrt = CRITICAL_TEMPERATURE;
gnvs->tpsv = PASSIVE_TEMPERATURE;
gnvs->tmax = MAX_TEMPERATURE;

View File

@ -20,6 +20,8 @@
#ifndef THERMAL_H
#define THERMAL_H
#define TEMPERATURE_SENSOR_ID 0 /* PECI */
/* Temperature which OS will shutdown at */
#define CRITICAL_TEMPERATURE 104

View File

@ -21,7 +21,7 @@
#define THERMAL_H
/* Control TDP Settings */
#define CTL_TDP_SENSOR_ID 1 /* PECI */
#define CTL_TDP_SENSOR_ID 0 /* PECI */
#define CTL_TDP_POWER_LIMIT 12 /* 12W */
#define CTL_TDP_THRESHOLD_OFF 68 /* Normal at 68C */
#define CTL_TDP_THRESHOLD_ON 73 /* Limited at 73C */

View File

@ -21,7 +21,7 @@
#define THERMAL_H
/* Config TDP Sensor ID */
#define CTDP_SENSOR_ID 1 /* PECI */
#define CTDP_SENSOR_ID 0 /* PECI */
/* Config TDP Nominal */
#define CTDP_NOMINAL_THRESHOLD_OFF 0