Fix MRC cache update delays
When no valid MRC cache area is found, the mrc_cache data structure was used without prior initialization. This sometimes caused a long delay when booting because compute_ip_checksum would checksum up to 4GB of memory. Change-Id: I6a0ca1aa618838bbc3d042be425700fc34b427f2 Signed-off-by: Stefan Reinauer <reinauer@google.com> Reviewed-on: http://review.coreboot.org/1277 Tested-by: build bot (Jenkins) Reviewed-by: Ronald G. Minnich <rminnich@gmail.com>
This commit is contained in:
parent
305b19dd7a
commit
48214899c3
|
@ -78,6 +78,24 @@ config CACHE_MRC_SIZE_KB
|
|||
int
|
||||
default 512
|
||||
|
||||
# FIXME: build from rom size
|
||||
config MRC_CACHE_BASE
|
||||
hex
|
||||
default 0xff800000
|
||||
|
||||
config MRC_CACHE_LOCATION
|
||||
hex
|
||||
default 0x370000
|
||||
|
||||
config MRC_CACHE_SIZE
|
||||
hex
|
||||
default 0x10000
|
||||
|
||||
config MRC_CACHE_ALIGNMENT
|
||||
hex
|
||||
default 0x1000
|
||||
|
||||
|
||||
config DCACHE_RAM_BASE
|
||||
hex
|
||||
default 0xff7e0000
|
||||
|
|
|
@ -118,7 +118,8 @@ struct mrc_data_container *find_current_mrc_cache(void)
|
|||
* from having no cache area at all
|
||||
*/
|
||||
return mrc_cache;
|
||||
} else {
|
||||
}
|
||||
|
||||
/* Search for the last filled entry in the region */
|
||||
while (is_mrc_cache(mrc_next)) {
|
||||
entry_id++;
|
||||
|
@ -129,6 +130,10 @@ struct mrc_data_container *find_current_mrc_cache(void)
|
|||
break;
|
||||
}
|
||||
entry_id--;
|
||||
|
||||
if (entry_id == -1) {
|
||||
printk(BIOS_ERR, "%s: No valid MRC cache found.\n", __func__);
|
||||
return NULL;
|
||||
}
|
||||
|
||||
/* Verify checksum */
|
||||
|
@ -150,6 +155,7 @@ struct mrc_data_container *find_current_mrc_cache(void)
|
|||
#if !defined(__PRE_RAM__)
|
||||
void update_mrc_cache(void)
|
||||
{
|
||||
printk(BIOS_DEBUG, "Updating MRC cache data.\n");
|
||||
struct mrc_data_container *current = cbmem_find(CBMEM_ID_MRCDATA);
|
||||
if (!current) {
|
||||
printk(BIOS_ERR, "No MRC cache in cbmem. Can't update flash.\n");
|
||||
|
@ -166,12 +172,14 @@ void update_mrc_cache(void)
|
|||
// 0. compare MRC data to last mrc-cache block (exit if same)
|
||||
struct mrc_data_container *cache;
|
||||
if ((cache = find_current_mrc_cache()) == NULL) {
|
||||
printk(BIOS_DEBUG, "Failure looking for current last block\n");
|
||||
printk(BIOS_DEBUG, "Failure looking for current last block.\n");
|
||||
return;
|
||||
}
|
||||
|
||||
if ((cache->mrc_data_size == current->mrc_data_size) && (memcmp(cache, current, cache->mrc_data_size) == 0)) {
|
||||
printk(BIOS_DEBUG, "MRC data in flash is up to date. No update.\n");
|
||||
if ((cache->mrc_data_size == current->mrc_data_size) &&
|
||||
(memcmp(cache, current, cache->mrc_data_size) == 0)) {
|
||||
printk(BIOS_DEBUG,
|
||||
"MRC data in flash is up to date. No update.\n");
|
||||
return;
|
||||
}
|
||||
|
||||
|
|