mb/siemens/mc_ehl2: Set RGMII output impedance manually
Measurements have shown that the automatic calibrated values for RGMII output impedances are too low. For this reason, set the PMOS value to 16 and the NMOS to 13. Change-Id: Ic3382889d3281faccb03819f9680a9763703b2a1 Signed-off-by: Mario Scheithauer <mario.scheithauer@siemens.com> Reviewed-on: https://review.coreboot.org/c/coreboot/+/73019 Reviewed-by: Werner Zeh <werner.zeh@siemens.com> Tested-by: build bot (Jenkins) <no-reply@coreboot.org>
This commit is contained in:
parent
481bfe6a8b
commit
7f1f8302fd
|
@ -191,6 +191,9 @@ chip soc/intel/elkhartlake
|
|||
# INTn is routed to LED[2] pin
|
||||
register "enable_int" = "true"
|
||||
register "downshift_cnt" = "2"
|
||||
register "force_mos" = "true"
|
||||
register "pmos_val" = "0xF"
|
||||
register "nmos_val" = "0xA"
|
||||
device mdio 0 on # PHY address
|
||||
ops m88e1512_ops
|
||||
end
|
||||
|
@ -207,6 +210,9 @@ chip soc/intel/elkhartlake
|
|||
# INTn is routed to LED[2] pin
|
||||
register "enable_int" = "true"
|
||||
register "downshift_cnt" = "2"
|
||||
register "force_mos" = "true"
|
||||
register "pmos_val" = "0xF"
|
||||
register "nmos_val" = "0xA"
|
||||
device mdio 1 on # PHY address
|
||||
ops m88e1512_ops
|
||||
end
|
||||
|
|
Loading…
Reference in New Issue