ec/smsc/mec1308/acpi: Replace LAnd() with ASL 2.0 syntax

Replace `LAnd (a, b)` with `a && b`.

Change-Id: I8c3323e1d367872e9f2a134eaf4ebd9e35f74313
Signed-off-by: Felix Singer <felixsinger@posteo.net>
Reviewed-on: https://review.coreboot.org/c/coreboot/+/60463
Tested-by: build bot (Jenkins) <no-reply@coreboot.org>
Reviewed-by: HAOUAS Elyes <ehaouas@noos.fr>
This commit is contained in:
Felix Singer 2021-12-29 15:37:08 +01:00
parent 6b0b1aafe7
commit 83ba290f6d
1 changed files with 5 additions and 7 deletions

View File

@ -133,8 +133,7 @@ Device (BAT0)
// //
Store (SWAB (BTPR), Local1) Store (SWAB (BTPR), Local1)
If (LAnd (LNotEqual (Local1, 0xFFFFFFFF), If (LNotEqual (Local1, 0xFFFFFFFF) && LGreaterEqual (Local1, 0x8000)) {
LGreaterEqual (Local1, 0x8000))) {
Xor (Local1, 0xFFFF, Local1) Xor (Local1, 0xFFFF, Local1)
Increment (Local1) Increment (Local1)
} }
@ -144,13 +143,12 @@ Device (BAT0)
// 2: BATTERY REMAINING CAPACITY // 2: BATTERY REMAINING CAPACITY
// //
Store (SWAB (BTRA), Local1) Store (SWAB (BTRA), Local1)
If (LAnd (LNotEqual (Local1, 0xFFFFFFFF), If (LNotEqual (Local1, 0xFFFFFFFF) && LGreaterEqual (Local1, 0x8000)) {
LGreaterEqual (Local1, 0x8000))) {
Xor (Local1, 0xFFFF, Local1) Xor (Local1, 0xFFFF, Local1)
Increment (Local1) Increment (Local1)
} }
If (LAnd (BFWK, LAnd (ACEX, LNot (Local0)))) { If (BFWK && ACEX && LNot (Local0)) {
// On AC power and battery is neither charging // On AC power and battery is neither charging
// nor discharging. Linux expects a full battery // nor discharging. Linux expects a full battery
// to report same capacity as last full charge. // to report same capacity as last full charge.
@ -159,8 +157,8 @@ Device (BAT0)
// See if within ~3% of full // See if within ~3% of full
ShiftRight (Local2, 5, Local3) ShiftRight (Local2, 5, Local3)
If (LAnd (LGreater (Local1, Subtract (Local2, Local3)), If (LGreater (Local1, Subtract (Local2, Local3)) &&
LLess (Local1, Add (Local2, Local3)))) LLess (Local1, Add (Local2, Local3)))
{ {
Store (Local2, Local1) Store (Local2, Local1)
} }