mb/asrock/h81m-hds: Allow "keep state" for power_on_after_fail

When I added the cmos.layout file, I did not realise that the
southbridge code cleverly emulated the "keep state" option.

Tested on an ASRock H81M-HDS. The `Keep` option works as it should.

Change-Id: I908e59d1e1eedefa6610e7f980afc3c04390a519
Signed-off-by: Tristan Corrick <tristan@corrick.kiwi>
Reviewed-on: https://review.coreboot.org/c/30102
Tested-by: build bot (Jenkins) <no-reply@coreboot.org>
Reviewed-by: Arthur Heymans <arthur@aheymans.xyz>
This commit is contained in:
Tristan Corrick 2018-12-07 20:06:16 +13:00 committed by Patrick Georgi
parent dcc249e295
commit 8fc49096f9
1 changed files with 5 additions and 1 deletions

View File

@ -55,7 +55,7 @@ entries
# coreboot config options: southbridge
408 1 e 1 nmi
409 2 e 1 power_on_after_fail
409 2 e 5 power_on_after_fail
# coreboot config options: check sums
984 16 h 0 check_sum
@ -84,6 +84,10 @@ enumerations
4 7 Debug
4 8 Spew
5 0 Disable
5 1 Enable
5 2 Keep
# -----------------------------------------------------------------
checksums