ec/lenovo/h8: Guard against EC bugs in the battery status logic.
On my Thinkpad with an H8-compatible ENE KB9012 EC (GDHT92WW 1.52), when the battery is nearly full and we switch from battery to AC by plugging in the cable, the current rate will not drop to 0 immediately, but the discharging state is cleared immediately. This leads to the code trying to process an invalid rate value >0x8000, leading to a displayed rate of >1000W. This patch changes the logic to deal with these corner cases. Change-Id: Ideb588d00757f259792e5ae97729e371b63a096c Signed-off-by: Tobias Diedrich <ranma+coreboot@tdiedrich.de> Reviewed-on: https://review.coreboot.org/18349 Tested-by: build bot (Jenkins) Reviewed-by: Paul Menzel <paulepanter@users.sourceforge.net> Reviewed-by: Martin Roth <martinroth@google.com>
This commit is contained in:
parent
80c314d64a
commit
9b798d7904
|
@ -97,21 +97,36 @@ Method(BSTA, 4, NotSerialized)
|
|||
Store(BAMA, Local1)
|
||||
Store(Arg0, PAGE) /* Battery dynamic information */
|
||||
|
||||
/*
|
||||
* Present rate is a 16bit signed int, positive while charging
|
||||
* and negative while discharging.
|
||||
*/
|
||||
Store(BAPR, Local2)
|
||||
|
||||
if (Arg2) // charging
|
||||
If (Arg2) // Charging
|
||||
{
|
||||
Or(2, Local0, Local0)
|
||||
|
||||
If (LGreaterEqual (Local2, 0x8000)) {
|
||||
}
|
||||
Else
|
||||
{
|
||||
If (Arg3) // Discharging
|
||||
{
|
||||
Or(1, Local0, Local0)
|
||||
// Negate present rate
|
||||
Subtract(0x10000, Local2, Local2)
|
||||
}
|
||||
Else // Full battery, force to 0
|
||||
{
|
||||
Store(0, Local2)
|
||||
}
|
||||
}
|
||||
|
||||
if (Arg3) // discharging
|
||||
{
|
||||
Or(1, Local0, Local0)
|
||||
Subtract(0x10000, Local2, Local2)
|
||||
/*
|
||||
* The present rate value must be positive now, if it is not we have an
|
||||
* EC bug or inconsistency and force the value to 0.
|
||||
*/
|
||||
If (LGreaterEqual (Local2, 0x8000)) {
|
||||
Store(0, Local2)
|
||||
}
|
||||
|
||||
Store(Local0, Index(Arg1, 0x00))
|
||||
|
|