mb/google/brask/variants/moli: Add DPTF setting in Moli
DPTF Policy and temperature sensor values from thermal team. BUG=b:236294162 TEST=emerge-brask coreboot Signed-off-by: Raihow Shi <raihow_shi@wistron.corp-partner.google.com> Change-Id: Iebcfb74c4bc719e6d8d8d9317435becd912eaf85 Reviewed-on: https://review.coreboot.org/c/coreboot/+/65657 Tested-by: build bot (Jenkins) <no-reply@coreboot.org> Reviewed-by: Sumeet R Pawnikar <sumeet.r.pawnikar@intel.com>
This commit is contained in:
parent
190afda543
commit
a955efc190
|
@ -35,6 +35,80 @@ chip soc/intel/alderlake
|
|||
register "tcss_ports[3]" = "TCSS_PORT_EMPTY" # Disable TCP3
|
||||
register "tcc_offset" = "0" # TCC of 100C
|
||||
device domain 0 on
|
||||
device ref dtt on
|
||||
chip drivers/intel/dptf
|
||||
## sensor information
|
||||
register "options.tsr[0].desc" = ""SSD""
|
||||
register "options.tsr[1].desc" = ""CPU_VR""
|
||||
register "options.tsr[2].desc" = ""DIMM""
|
||||
|
||||
# TODO: below values are initial reference values only
|
||||
## Active Policy
|
||||
register "policies.active" = "{
|
||||
[0] = {
|
||||
.target = DPTF_CPU,
|
||||
.thresholds = {
|
||||
TEMP_PCT(85, 90),
|
||||
TEMP_PCT(80, 80),
|
||||
TEMP_PCT(75, 70),
|
||||
}
|
||||
}
|
||||
}"
|
||||
|
||||
## Passive Policy
|
||||
register "policies.passive" = "{
|
||||
[0] = DPTF_PASSIVE(CPU, CPU, 95, 5000),
|
||||
[1] = DPTF_PASSIVE(CPU, TEMP_SENSOR_0, 75, 5000),
|
||||
[2] = DPTF_PASSIVE(CPU, TEMP_SENSOR_1, 75, 5000),
|
||||
[3] = DPTF_PASSIVE(CPU, TEMP_SENSOR_2, 75, 5000),
|
||||
}"
|
||||
|
||||
## Critical Policy
|
||||
register "policies.critical" = "{
|
||||
[0] = DPTF_CRITICAL(CPU, 105, SHUTDOWN),
|
||||
[1] = DPTF_CRITICAL(TEMP_SENSOR_0, 85, SHUTDOWN),
|
||||
[2] = DPTF_CRITICAL(TEMP_SENSOR_1, 85, SHUTDOWN),
|
||||
[3] = DPTF_CRITICAL(TEMP_SENSOR_2, 85, SHUTDOWN),
|
||||
}"
|
||||
|
||||
register "controls.power_limits" = "{
|
||||
.pl1 = {
|
||||
.min_power = 15000,
|
||||
.max_power = 55000,
|
||||
.time_window_min = 28 * MSECS_PER_SEC,
|
||||
.time_window_max = 32 * MSECS_PER_SEC,
|
||||
.granularity = 200,
|
||||
},
|
||||
.pl2 = {
|
||||
.min_power = 55000,
|
||||
.max_power = 55000,
|
||||
.time_window_min = 28 * MSECS_PER_SEC,
|
||||
.time_window_max = 32 * MSECS_PER_SEC,
|
||||
.granularity = 1000,
|
||||
}
|
||||
}"
|
||||
|
||||
## Fan Performance Control (Percent, Speed, Noise, Power)
|
||||
register "controls.fan_perf" = "{
|
||||
[0] = { 90, 6700, 220, 2200, },
|
||||
[1] = { 80, 5800, 180, 1800, },
|
||||
[2] = { 70, 5000, 145, 1450, },
|
||||
[3] = { 60, 4900, 115, 1150, },
|
||||
[4] = { 50, 3838, 90, 900, },
|
||||
[5] = { 40, 2904, 55, 550, },
|
||||
[6] = { 30, 2337, 30, 300, },
|
||||
[7] = { 20, 1608, 15, 150, },
|
||||
[8] = { 10, 800, 10, 100, },
|
||||
[9] = { 0, 0, 0, 50, }
|
||||
}"
|
||||
|
||||
## Fan options
|
||||
register "options.fan.fine_grained_control" = "1"
|
||||
register "options.fan.step_size" = "2"
|
||||
|
||||
device generic 0 alias dptf_policy on end
|
||||
end
|
||||
end
|
||||
device ref tcss_dma0 on
|
||||
chip drivers/intel/usb4/retimer
|
||||
register "dfp[0].power_gpio" = "ACPI_GPIO_OUTPUT_ACTIVE_HIGH(GPP_E4)"
|
||||
|
|
Loading…