mb/system76/lemp9: update power limits
Tested on lemp9, power limits are adjusted from the previously low values to the values the thermal system can handle. This was determined by increasing the values and running the system at 100% CPU utilization until thermal throttling occured and the chassis temperature became uncomfortable. Signed-off-by: Jeremy Soller <jeremy@system76.com> Change-Id: I5e176e9d98376f8e2dc415e4397efc456869e72d Reviewed-on: https://review.coreboot.org/c/coreboot/+/43624 Reviewed-by: Michael Niewöhner <foss@mniewoehner.de> Reviewed-by: Angel Pons <th3fanbus@gmail.com> Tested-by: build bot (Jenkins) <no-reply@coreboot.org>
This commit is contained in:
parent
d7775b763f
commit
b349f258a9
|
@ -25,8 +25,8 @@ chip soc/intel/cannonlake
|
|||
# CPU (soc/intel/cannonlake/cpu.c)
|
||||
# Power limit
|
||||
register "power_limits_config" = "{
|
||||
.tdp_pl1_override = 15,
|
||||
.tdp_pl2_override = 25,
|
||||
.tdp_pl1_override = 20,
|
||||
.tdp_pl2_override = 30,
|
||||
}"
|
||||
|
||||
# Enable "Intel Speed Shift Technology"
|
||||
|
|
Loading…
Reference in New Issue