From d13059a5a2acfbd2e55484b5c6a161286d4e956c Mon Sep 17 00:00:00 2001 From: Rudolf Marek Date: Mon, 7 Jul 2014 22:40:12 +0200 Subject: [PATCH] asus/f2a85-m: Switch off automatic fan control for fan2 The fan2 (chasis fan) was set to automatic mode, but the registers for smart guardian have still default value which will stop it. Run it in manual mode for now. Change-Id: Ic2c2414ac88abba77a9e7a129788f9777e7e5ad5 Signed-off-by: Rudolf Marek Reviewed-on: http://review.coreboot.org/6217 Tested-by: build bot (Jenkins) Reviewed-by: Edward O'Callaghan --- src/mainboard/asus/f2a85-m/devicetree.cb | 2 +- 1 file changed, 1 insertion(+), 1 deletion(-) diff --git a/src/mainboard/asus/f2a85-m/devicetree.cb b/src/mainboard/asus/f2a85-m/devicetree.cb index 25fe5db5cd..9ac55743ce 100644 --- a/src/mainboard/asus/f2a85-m/devicetree.cb +++ b/src/mainboard/asus/f2a85-m/devicetree.cb @@ -65,7 +65,7 @@ chip northbridge/amd/agesa/family15tn/root_complex register hwm_main_ctl_register = "0x33" register hwm_adc_temp_chan_en_reg = "0x38" register hwm_fan1_ctl_pwm = "0x00" - register hwm_fan2_ctl_pwm = "0x80" + register hwm_fan2_ctl_pwm = "0x00" register hwm_fan3_ctl_pwm = "0x00" device pnp 2e.0 off # Floppy