soc/intel/broadwell: Remove _ADR from SerialIO ACPI devices

SerialIO is in ACPI mode for google/auron and intel/wtm2, and is
disabled for google/jecht and purism/librem_bdw. Since Broadwell
SerialIO is never used in PCI mode, _ADR can safely be dropped.

Change-Id: I9a99b8209b5c139146012aa4a92f563692b62c5e
Signed-off-by: Angel Pons <th3fanbus@gmail.com>
Reviewed-on: https://review.coreboot.org/c/coreboot/+/46972
Tested-by: build bot (Jenkins) <no-reply@coreboot.org>
Reviewed-by: HAOUAS Elyes <ehaouas@noos.fr>
Reviewed-by: Michael Niewöhner <foss@mniewoehner.de>
This commit is contained in:
Angel Pons 2020-10-29 18:07:20 +01:00 committed by Patrick Georgi
parent 4f880b9ab8
commit d152837d34
1 changed files with 0 additions and 8 deletions

View File

@ -122,7 +122,6 @@ Device (SDMA)
// Serial IO DMA Controller
Name (_HID, "INTL9C60")
Name (_UID, 1)
Name (_ADR, 0x00150000)
// BAR0 is assigned during PCI enumeration and saved into NVS
Name (RBUF, ResourceTemplate ()
@ -168,7 +167,6 @@ Device (I2C0)
Return ("INT33C2")
}
Name (_UID, 1)
Name (_ADR, 0x00150001)
Name (SSCN, Package () { 432, 507, 30 })
Name (FMCN, Package () { 72, 160, 30 })
@ -245,7 +243,6 @@ Device (I2C1)
Return ("INT33C3")
}
Name (_UID, 1)
Name (_ADR, 0x00150002)
Name (SSCN, Package () { 432, 507, 30 })
Name (FMCN, Package () { 72, 160, 30 })
@ -322,7 +319,6 @@ Device (SPI0)
Return ("INT33C0")
}
Name (_UID, 1)
Name (_ADR, 0x00150003)
// BAR0 is assigned during PCI enumeration and saved into NVS
Name (RBUF, ResourceTemplate ()
@ -384,7 +380,6 @@ Device (SPI1)
Return ("INT33C1")
}
Name (_UID, 1)
Name (_ADR, 0x00150004)
// BAR0 is assigned during PCI enumeration and saved into NVS
Name (RBUF, ResourceTemplate ()
@ -458,7 +453,6 @@ Device (UAR0)
Return ("INT33C4")
}
Name (_UID, 1)
Name (_ADR, 0x00150005)
// BAR0 is assigned during PCI enumeration and saved into NVS
Name (RBUF, ResourceTemplate ()
@ -532,7 +526,6 @@ Device (UAR1)
Return ("INT33C5")
}
Name (_UID, 1)
Name (_ADR, 0x00150006)
// BAR0 is assigned during PCI enumeration and saved into NVS
Name (RBUF, ResourceTemplate ()
@ -595,7 +588,6 @@ Device (SDIO)
}
Name (_CID, "PNP0D40")
Name (_UID, 1)
Name (_ADR, 0x00170000)
// BAR0 is assigned during PCI enumeration and saved into NVS
Name (RBUF, ResourceTemplate ()