cfe15a2088
1. Fix PCIe slot capabilities not being really read from an IIO root port device. The Hot-Plug capability of IIO root port cannot be enabled due to FSP limitation (v2.1-0.2.2.0), but the code should reflect the true capabilities by reading the root port device's CSR. 2. Initialize the characteristics flags to 0 in the for-loop to fix the issue of the flags values persists to the next iterations. Tested=On OCP Delta Lake, dmidecode -t 9 shows the expected results. For example without the fix it shows 'Hot-plug devices are supported' but in fact it's not: System Slot Information Designation: SSD1_M2_Data_Drive Type: x4 PCI Express 3 x4 Current Usage: Available Length: Short ID: 1 Characteristics: 3.3 V is provided PME signal is supported Hot-plug devices are supported Bus Address: 0000:00:1d.0 With the fix it shows the correct result: Handle 0x0016, DMI type 9, 19 bytes System Slot Information Designation: SSD1_M2_Data_Drive Type: x4 PCI Express 3 x4 Current Usage: Available Length: Short ID: 1 Characteristics: 3.3 V is provided PME signal is supported Bus Address: 0000:00:1d.0 Change-Id: Iea437cdf3da5410b6b7a749a1be970f0948d92d9 Signed-off-by: Johnny Lin <johnny_lin@wiwynn.com> Reviewed-on: https://review.coreboot.org/c/coreboot/+/58100 Reviewed-by: Johnny Lin <Johnny_Lin@wiwynn.com> Reviewed-by: Paul Menzel <paulepanter@mailbox.org> Reviewed-by: Angel Pons <th3fanbus@gmail.com> Reviewed-by: Jonathan Zhang <jonzhang@fb.com> Tested-by: build bot (Jenkins) <no-reply@coreboot.org> |
||
---|---|---|
.. | ||