173 lines
4.2 KiB
C
173 lines
4.2 KiB
C
|
/* Copyright 2018 The Chromium OS Authors. All rights reserved.
|
||
|
* Use of this source code is governed by a BSD-style license that can be
|
||
|
* found in the LICENSE file.
|
||
|
*
|
||
|
* Battery pack vendor provided charging profile
|
||
|
*/
|
||
|
|
||
|
#include "battery.h"
|
||
|
#include "charge_state.h"
|
||
|
#include "charger_mt6370.h"
|
||
|
#include "console.h"
|
||
|
#include "driver/battery/max17055.h"
|
||
|
#include "ec_commands.h"
|
||
|
#include "util.h"
|
||
|
|
||
|
#define TEMP_OUT_OF_RANGE TEMP_ZONE_COUNT
|
||
|
|
||
|
#define BATT_ID 0
|
||
|
|
||
|
#define BATTERY_SIMPLO_CHARGE_MIN_TEMP 0
|
||
|
#define BATTERY_SIMPLO_CHARGE_MAX_TEMP 60
|
||
|
|
||
|
#define CPRINTS(format, args...) cprints(CC_CHARGER, format, ## args)
|
||
|
|
||
|
enum battery_type {
|
||
|
BATTERY_SIMPLO = 0,
|
||
|
BATTERY_COUNT
|
||
|
};
|
||
|
|
||
|
static const struct battery_info info[] = {
|
||
|
[BATTERY_SIMPLO] = {
|
||
|
.voltage_max = 4400,
|
||
|
.voltage_normal = 3860,
|
||
|
.voltage_min = 3000,
|
||
|
.precharge_current = 256,
|
||
|
.start_charging_min_c = 0,
|
||
|
.start_charging_max_c = 45,
|
||
|
.charging_min_c = 0,
|
||
|
.charging_max_c = 60,
|
||
|
.discharging_min_c = -20,
|
||
|
.discharging_max_c = 60,
|
||
|
},
|
||
|
};
|
||
|
|
||
|
static const struct max17055_batt_profile batt_profile[] = {
|
||
|
[BATTERY_SIMPLO] = {
|
||
|
.is_ez_config = 1,
|
||
|
.design_cap = MAX17055_DESIGNCAP_REG(6910),
|
||
|
.ichg_term = MAX17055_ICHGTERM_REG(235),
|
||
|
.v_empty_detect = MAX17055_VEMPTY_REG(3000, 3600),
|
||
|
},
|
||
|
};
|
||
|
|
||
|
static const struct max17055_alert_profile alert_profile[] = {
|
||
|
[BATTERY_SIMPLO] = {
|
||
|
.v_alert_mxmn = VALRT_DISABLE,
|
||
|
.t_alert_mxmn = MAX17055_TALRTTH_REG(
|
||
|
BATTERY_SIMPLO_CHARGE_MAX_TEMP,
|
||
|
BATTERY_SIMPLO_CHARGE_MIN_TEMP),
|
||
|
.s_alert_mxmn = SALRT_DISABLE,
|
||
|
.i_alert_mxmn = IALRT_DISABLE,
|
||
|
},
|
||
|
};
|
||
|
|
||
|
const struct max17055_batt_profile *max17055_get_batt_profile(void)
|
||
|
{
|
||
|
return &batt_profile[BATT_ID];
|
||
|
}
|
||
|
|
||
|
const struct max17055_alert_profile *max17055_get_alert_profile(void)
|
||
|
{
|
||
|
return &alert_profile[BATT_ID];
|
||
|
}
|
||
|
|
||
|
const struct battery_info *battery_get_info(void)
|
||
|
{
|
||
|
return &info[BATT_ID];
|
||
|
}
|
||
|
|
||
|
enum battery_disconnect_state battery_get_disconnect_state(void)
|
||
|
{
|
||
|
if (battery_is_present() == BP_YES)
|
||
|
return BATTERY_NOT_DISCONNECTED;
|
||
|
return BATTERY_DISCONNECTED;
|
||
|
}
|
||
|
|
||
|
int charger_profile_override(struct charge_state_data *curr)
|
||
|
{
|
||
|
/* battery temp in 0.1 deg C */
|
||
|
int bat_temp_c = curr->batt.temperature - 2731;
|
||
|
|
||
|
/*
|
||
|
* Keep track of battery temperature range:
|
||
|
*
|
||
|
* ZONE_0 ZONE_1 ZONE_2
|
||
|
* -----+--------+--------+------------+----- Temperature (C)
|
||
|
* t0 t1 t2 t3
|
||
|
*/
|
||
|
enum {
|
||
|
TEMP_ZONE_0, /* t0 < bat_temp_c <= t1 */
|
||
|
TEMP_ZONE_1, /* t1 < bat_temp_c <= t2 */
|
||
|
TEMP_ZONE_2, /* t2 < bat_temp_c <= t3 */
|
||
|
TEMP_ZONE_COUNT
|
||
|
} temp_zone;
|
||
|
|
||
|
static struct {
|
||
|
int temp_min; /* 0.1 deg C */
|
||
|
int temp_max; /* 0.1 deg C */
|
||
|
int desired_current; /* mA */
|
||
|
int desired_voltage; /* mV */
|
||
|
} temp_zones[BATTERY_COUNT][TEMP_ZONE_COUNT] = {
|
||
|
[BATTERY_SIMPLO] = {
|
||
|
/* TEMP_ZONE_0 */
|
||
|
{BATTERY_SIMPLO_CHARGE_MIN_TEMP * 10, 150, 1772, 4376},
|
||
|
/* TEMP_ZONE_1 */
|
||
|
{150, 450, 4020, 4376},
|
||
|
/* TEMP_ZONE_2 */
|
||
|
{450, BATTERY_SIMPLO_CHARGE_MAX_TEMP * 10, 3350, 4300},
|
||
|
},
|
||
|
};
|
||
|
BUILD_ASSERT(ARRAY_SIZE(temp_zones[0]) == TEMP_ZONE_COUNT);
|
||
|
BUILD_ASSERT(ARRAY_SIZE(temp_zones) == BATTERY_COUNT);
|
||
|
|
||
|
if ((curr->batt.flags & BATT_FLAG_BAD_TEMPERATURE) ||
|
||
|
(bat_temp_c < temp_zones[BATT_ID][0].temp_min) ||
|
||
|
(bat_temp_c >= temp_zones[BATT_ID][TEMP_ZONE_COUNT - 1].temp_max))
|
||
|
temp_zone = TEMP_OUT_OF_RANGE;
|
||
|
else {
|
||
|
for (temp_zone = 0; temp_zone < TEMP_ZONE_COUNT; temp_zone++) {
|
||
|
if (bat_temp_c <
|
||
|
temp_zones[BATT_ID][temp_zone].temp_max)
|
||
|
break;
|
||
|
}
|
||
|
}
|
||
|
|
||
|
if (curr->state != ST_CHARGE)
|
||
|
return 0;
|
||
|
|
||
|
switch (temp_zone) {
|
||
|
case TEMP_ZONE_0:
|
||
|
case TEMP_ZONE_1:
|
||
|
case TEMP_ZONE_2:
|
||
|
curr->requested_current =
|
||
|
temp_zones[BATT_ID][temp_zone].desired_current;
|
||
|
curr->requested_voltage =
|
||
|
temp_zones[BATT_ID][temp_zone].desired_voltage;
|
||
|
break;
|
||
|
case TEMP_OUT_OF_RANGE:
|
||
|
curr->requested_current = curr->requested_voltage = 0;
|
||
|
curr->batt.flags &= ~BATT_FLAG_WANT_CHARGE;
|
||
|
curr->state = ST_IDLE;
|
||
|
break;
|
||
|
}
|
||
|
|
||
|
#ifdef VARIANT_KUKUI_CHARGER_MT6370
|
||
|
mt6370_charger_profile_override(curr);
|
||
|
#endif /* CONFIG_CHARGER_MT6370 */
|
||
|
|
||
|
return 0;
|
||
|
}
|
||
|
|
||
|
enum ec_status charger_profile_override_get_param(uint32_t param,
|
||
|
uint32_t *value)
|
||
|
{
|
||
|
return EC_RES_INVALID_PARAM;
|
||
|
}
|
||
|
|
||
|
enum ec_status charger_profile_override_set_param(uint32_t param,
|
||
|
uint32_t value)
|
||
|
{
|
||
|