mb/google/zork: Update telemetry settings for morphius
Correct the two load line slope settings for the SVID3 telemetry. AGESA sends these values to the SMU, which accepts them as units of current. Proper calibration is determined by the AMD SDLE tool and the Stardust test. BUG=b:168265881 BRANCH=zork TEST=emerge-zork coreboot Change-Id: Id6c4f1a92d7f2ad293df7b63694e9665b85f8018 Signed-off-by: Kevin Chiu <kevin.chiu@quantatw.com> Reviewed-on: https://review.coreboot.org/c/coreboot/+/46472 Reviewed-by: Martin Roth <martinroth@google.com> Reviewed-by: Chris Wang <chris.wang@amd.corp-partner.google.com> Tested-by: build bot (Jenkins) <no-reply@coreboot.org>
This commit is contained in:
parent
fb620109a4
commit
0088b3df28
|
@ -16,9 +16,9 @@ chip soc/amd/picasso
|
|||
register "sustained_power_limit" = "12000" #mw
|
||||
register "thermctl_limit" = "100" #degrees C
|
||||
|
||||
register "telemetry_vddcr_vdd_slope" = "78709" #mA
|
||||
register "telemetry_vddcr_vdd_slope" = "62852" #mA
|
||||
register "telemetry_vddcr_vdd_offset" = "0"
|
||||
register "telemetry_vddcr_soc_slope" = "29035" #mA
|
||||
register "telemetry_vddcr_soc_slope" = "28022" #mA
|
||||
register "telemetry_vddcr_soc_offset" = "0"
|
||||
|
||||