mb/siemens/mc_ehl: Enable write access for SPD EEPROM on mc_ehl1
The address space of possible SPD-EEPROMs 0x50..0x53 on the SMBus interface is per default write-protected in FSP. This avoids that an SPD-EEPROM on a DRAM module gets overwritten by the host. On mc_ehl1, memory-down configuration is used and there is no SPD EEPROM available. Nevertheless, there is a general purpose EEPROM on the same address available which needs to stay writeable. This patch disables the default-enabled write protect feature for the SPD-EEPROM addresses just for mc_ehl1. Test=Boot into Linux and make sure a write access into the EEPROM is possible. Change-Id: I6b0fcdbeb0dbf971cfdceb70d6f4845765a3bdb6 Signed-off-by: Werner Zeh <werner.zeh@siemens.com> Reviewed-on: https://review.coreboot.org/c/coreboot/+/79334 Tested-by: build bot (Jenkins) <no-reply@coreboot.org> Reviewed-by: Jan Samek <jan.samek@siemens.com>
This commit is contained in:
parent
fd1c2f488f
commit
722c0b7b21
|
@ -38,4 +38,8 @@ void mainboard_memory_init_params(FSPM_UPD *memupd)
|
|||
|
||||
/* Enable Row-Hammer prevention */
|
||||
memupd->FspmConfig.RhPrevention = 1;
|
||||
if (CONFIG(BOARD_SIEMENS_MC_EHL1)) {
|
||||
/* Allow writes to EEPROM addresses 0x50..0x57. */
|
||||
memupd->FspmConfig.SmbusSpdWriteDisable = 0;
|
||||
}
|
||||
}
|
||||
|
|