asus/f2a85-m: Switch off automatic fan control for fan2

The fan2 (chasis fan) was set to automatic mode, but the
registers for smart guardian have still default value which
will stop it. Run it in manual mode for now.

Change-Id: Ic2c2414ac88abba77a9e7a129788f9777e7e5ad5
Signed-off-by: Rudolf Marek <r.marek@assembler.cz>
Reviewed-on: http://review.coreboot.org/6217
Tested-by: build bot (Jenkins)
Reviewed-by: Edward O'Callaghan <eocallaghan@alterapraxis.com>
This commit is contained in:
Rudolf Marek 2014-07-07 22:40:12 +02:00
parent 6dbbe2ee96
commit d13059a5a2
1 changed files with 1 additions and 1 deletions

View File

@ -65,7 +65,7 @@ chip northbridge/amd/agesa/family15tn/root_complex
register hwm_main_ctl_register = "0x33"
register hwm_adc_temp_chan_en_reg = "0x38"
register hwm_fan1_ctl_pwm = "0x00"
register hwm_fan2_ctl_pwm = "0x80"
register hwm_fan2_ctl_pwm = "0x00"
register hwm_fan3_ctl_pwm = "0x00"
device pnp 2e.0 off # Floppy