coreboot-kgpe-d16/src/mainboard/siemens
Werner Zeh 70ca32e0ba siemens/mc_tcu3: Don't try to init unsupported panel type
The LCD panel type is read using 4 GPIOs. Of these 16 possible
combinations only 5 are supported right now. If the GPIO setting encodes
an unsupported panel type, there will be no matching hwinfo.hex in cbfs.
Therefore it makes no sense to try to initialize the DisplayPort-2-LVDS
converter. Leave the function instead in this case.

Change-Id: If8c67a3f5be762758d516c4939dd1de4ff1c8ba5
Signed-off-by: Werner Zeh <werner.zeh@siemens.com>
Reviewed-on: https://review.coreboot.org/14743
Tested-by: build bot (Jenkins)
Reviewed-by: Paul Menzel <paulepanter@users.sourceforge.net>
Reviewed-by: Mario Scheithauer <mario.scheithauer@siemens.com>
2016-05-10 14:51:10 +02:00
..
mc_bdx1 siemens/mc_bdx1: Add new mainboard. 2016-04-29 06:29:54 +02:00
mc_tcu3 siemens/mc_tcu3: Don't try to init unsupported panel type 2016-05-10 14:51:10 +02:00
sitemp_g1p1 southbridge/amd/sb600: Update HPET base address with #define 2015-12-16 00:56:08 +01:00