88d4e82b33
The BIOS log was looking in the spd data for the part name, but part names are stripped from generic SPDs. For these cases, a mainboard can override the dram part number string, so the spd logging code needs to check for an override string when logging the dram part number. Change print_spd_info() to use an override string if declared. BUG=b:168724473 TEST="emerge-volteer coreboot chromeos-bootimage", flash and boot volteer2 and verify that the BIOS log shows a part name when logging SPD information: SPD: module part number is K4U6E3S4AA-MGCL I also modified volteer to not override the part name and verified that this change did as expected and printed a blank string. Change-Id: I91971e07c450492dbb0588abd1c3c692ee0d3bb0 Signed-off-by: Nick Vaccaro <nvaccaro@google.com> Reviewed-on: https://review.coreboot.org/c/coreboot/+/45459 Reviewed-by: Furquan Shaikh <furquan@google.com> Tested-by: build bot (Jenkins) <no-reply@coreboot.org> |
||
---|---|---|
.. | ||